The "Big Three" of Biocompatibility Testing

What are the big three?
Beyond the big three 
References 
Further reading 


Biocompatibility testing is performed on medical devices to ensure that they will not cause any adverse effects once in contact with or implanted into a patient, and as a standard, all such devices must be assessed with regards to cytotoxicity, sensitization, and irritation, often termed the "big three."

The evaluation of all medical devices for biological contact is set out by international standard ISO 10993, which includes personal protective equipment such as gloves and masks, gowns worn by the patient, surgical tools, and any other implanted or externally applied device.

Image Credit: totojang1977/Shutterstock.com

Image Credit: totojang1977/Shutterstock.com

 

Patients may come into contact with medical devices in a variety of settings that call for differing biocompatibility testing, directly or indirectly, for long or short periods, and potentially in the presence of fluids that would encourage chemical leaching and allow the transport of toxic substances through the bloodstream.

The importance of the big three and other biocompatibility testing will be explored further below.

What are the big three?

Cytotixicity

Cytotoxicity is the measure of direct toxicity towards cells and is routinely tested for biocompatibility by incubating the medical device in mammalian cell culture to allow native proteins and other biomolecules to interact with and adhere to the surface as they would in situ. The device and/or any leeched materials (extract) are then removed from culture and placed in contact with relevant cells in vitro, either directly or with a porous separating layer, to establish the toxicity of the device to adjacent cells by measuring cell viability after that at various time points.

Any number of cell viability assays may be appropriately applied to determine material cytotoxicity towards a particular cell line, or alternatively, high-throughput cell analysis techniques such as flow cytometry may be employed. Importantly, cytotoxicity testing can be used to reveal the mechanism by which the material is inducing cell death, allowing appropriate design changes to be made.

ISO 10993-5 calls for the use of L929 mouse fibroblast cells as a standard and advises qualitative evaluation of cells by microscopy and cytochemical staining, where changes in cell morphology and membrane integrity are indicative of material toxicity.

Sensitization

Sensitization biocompatibility tests measure the sensitizing and allergic response to medical devices, generally performed by the simple application of the device to animals and subsequent monitoring.

Image Credit: Artur Wnorowski/Shutterstock.com

Image Credit: Artur Wnorowski/Shutterstock.com

In the case of externally applied devices, itchy rashes and blistering can easily be observed on the skin should sensitization or an allergic response occur, though various tests are employed to monitor the biochemical reaction of the animal to the device. For example, ISO 10993-10 advises the use of the murine local lymph node assay, where lymphocyte proliferation in response to device exposure is determined by extraction of the lymph nodes behind the ears.

Irritation

Similarly, irritation testing is performed to ensure that medical devices do not impose serious irritation reactions once implanted and is usually achieved in vivo, though several in vitro skin and eye alternatives are available and increasingly employed. Irritation testing differs from sensitization testing in acuteness, where irritation is a more immediate, often chemical, reaction.

To ensure relevance to humans, ISO 10993-10 recommends human skin irritation tests only if animal tests prove negative, as many chemical irritation reactions may depend on human biology.

Beyond the big three

Devices that come into contact with the interior of the body are subjected to much more extensive testing relevant to long-term and intense exposure that may not be covered by the "big three," a term coined early on in the field of biocompatibility testing prior to additional distinctions being made. For example, the cytotoxicity of a material may be distinct from its systemic toxicity and chronic toxicity, which measure full body and long-term toxicity, respectively.

Tests for genotoxicity and carcinogenicity are also performed on implanted medical devices to check for gene point mutations or chromosomal damage resulting from prolonged contact. No single test can check for each type of genotoxic mechanism possible of a material or its extract; thus, a battery of tests are typically applied.

Image Credit: Ivan_Shenets/Shutterstock.com

Image Credit: Ivan_Shenets/Shutterstock.com

Gene mutations are identified following in vitro exposure of mammalian or bacterial cells to the device, and if positive, further in vivo tests are performed in rodents. Chromosomal damage can be detected by in vitro staining and observation by microscope. If a material is found to be genotoxic, then it is presumed carcinogenic, but separate carcinogenicity tests are also performed for implantable devices thought to bear a risk of causing cancer by any means, usually consisting mainly of long-term exposure of animals to the device.

These tests are concerned with the material influence of an implanted device and any influence generated by electromagnetic fields or other non-chemical means. For example, cochlear implants receive a radio frequency signal around which concerns have been raised given the proximity of the device to the brain. However, no study has demonstrated a higher incidence of brain cancers amongst those with a cochlear implant. Tests for genotoxicity, carcinogenicity and reproductive toxicity are set out in international standard ISO 10993-3, which is applied to all medical devices intended for implantation.

References

Further Reading

Last Updated: Sep 18, 2022

Michael Greenwood

Written by

Michael Greenwood

Michael graduated from the University of Salford with a Ph.D. in Biochemistry in 2023, and has keen research interests towards nanotechnology and its application to biological systems. Michael has written on a wide range of science communication and news topics within the life sciences and related fields since 2019, and engages extensively with current developments in journal publications.  

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Greenwood, Michael. (2022, September 18). The "Big Three" of Biocompatibility Testing. News-Medical. Retrieved on November 11, 2024 from https://www.news-medical.net/life-sciences/The-Big-Three-of-Biocompatibility-Testing.aspx.

  • MLA

    Greenwood, Michael. "The "Big Three" of Biocompatibility Testing". News-Medical. 11 November 2024. <https://www.news-medical.net/life-sciences/The-Big-Three-of-Biocompatibility-Testing.aspx>.

  • Chicago

    Greenwood, Michael. "The "Big Three" of Biocompatibility Testing". News-Medical. https://www.news-medical.net/life-sciences/The-Big-Three-of-Biocompatibility-Testing.aspx. (accessed November 11, 2024).

  • Harvard

    Greenwood, Michael. 2022. The "Big Three" of Biocompatibility Testing. News-Medical, viewed 11 November 2024, https://www.news-medical.net/life-sciences/The-Big-Three-of-Biocompatibility-Testing.aspx.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
AI in healthcare shows promise in trials but needs real-world testing to ensure effectiveness