Mass spectrometry (MS) is a technique used to measure the masses of molecules and fragments formed during vaporization and ionization.

Credit: Egorov Artem/Shutterstock.com

The precision of the mass determination makes it possible to identify the molecule accurately. A combination of high sensitivity and precise molecular identification has made MS a ubiquitous technology in life science laboratories.

Time-of-flight mass spectrometry (TOF-MS) uses a detection method based on the time it takes the molecular fragments to arrive at a detector after they are vaporized. For example, in matrix-assisted laser desorption/ionization time-of-flight MS (MALDI-TOF-MS), a laser is used to ionize large molecules which are then separated based on flight times to the detector.

Electrospray (ESI-TOF-MS) and gas chromatography (GC-TOF-MS) are other variations on time-of-flight mass spectrometry.

These instruments are typically very large. However, advancing technologies like miniaturized lasers and ultra-short ion flight tubes have enabled the development of miniature and portable devices. In addition, miniature TOF analyzers require miniaturized control systems to generate electric and magnetic fields and fluid handling technologies (microfluidics).

Applications of miniature time of flight spectrometry

Miniature TOF technology enables MS analysis of samples in the field or at the site of the sample. It has applications across many industries, including:

  • Healthcare: Analysis of patient samples at the bedside
  • Firefighters: Analysis of potentially hazardous samples during an emergency situation
  • Airports: Detection of traces of explosive material

Some examples of miniature TOF instruments are summarized below:

One design for a miniature TOF-MS makes use of a gridless, focusing ion source, an ion reflector constructed of circuitboard material, and an improved microchannel plate detector assembly.

These innovations allow for very high extraction energies and significant reduction in noise. Tests of the instrument showed improved resolution compared to previous models. The design was inexpensive and rugged for portability in the field.

Another instrument was developed for space exploration. The device is designed with small-scale planetary missions in mind. It would need to be suitable for remote operation during long-stay surface missions on multiple small bodies such as moons, Mars, and Mercury, with sample return capabilities.

The goal of the device is analysis of solid materials such as rocks and soil. The design incorporates normal-incidence ultraviolet pulsed laser desorption, a curved-field reflectron, and a gridless ion source. Field tests showed that results were comparable. This design allows a TOF instrument potentially as small as a soda can, without loss of low range detection ability.

MULTUM-S II

The miniature multiturn time-of-flight analyzer (MULTUM-S II) consists of an electron ionization source, multiturn TOF ion optics, a detector, a vacuum system, and electronic circuits. The multiturn TOF analyzer is made of four electrostatic toroidal sectors and two electric toroidal sectors. The total size is 50 cm by 57 cm x 30 cm and the weight is 35 kg.

The inventors were able to separate and weigh pyridine and the isotopic component of benzene at a high mass resolution. It also successfully separated CO2 and N20 gases, which have a mass difference of 0.01 Da.

Further Reading

Last Updated: Feb 26, 2019

Dr. Catherine Shaffer

Written by

Dr. Catherine Shaffer

Catherine Shaffer is a freelance science and health writer from Michigan. She has written for a wide variety of trade and consumer publications on life sciences topics, particularly in the area of drug discovery and development. She holds a Ph.D. in Biological Chemistry and began her career as a laboratory researcher before transitioning to science writing. She also writes and publishes fiction, and in her free time enjoys yoga, biking, and taking care of her pets.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Shaffer, Catherine. (2019, February 26). Miniature Time of Flight. News-Medical. Retrieved on November 11, 2024 from https://www.news-medical.net/life-sciences/Miniature-Time-of-Flight.aspx.

  • MLA

    Shaffer, Catherine. "Miniature Time of Flight". News-Medical. 11 November 2024. <https://www.news-medical.net/life-sciences/Miniature-Time-of-Flight.aspx>.

  • Chicago

    Shaffer, Catherine. "Miniature Time of Flight". News-Medical. https://www.news-medical.net/life-sciences/Miniature-Time-of-Flight.aspx. (accessed November 11, 2024).

  • Harvard

    Shaffer, Catherine. 2019. Miniature Time of Flight. News-Medical, viewed 11 November 2024, https://www.news-medical.net/life-sciences/Miniature-Time-of-Flight.aspx.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Study identifies cellular and molecular roots of individual brain connectivity differences